Skip to content

Versiclad: Insulated Roofing Corrolink S 1000

Insulated Roofing Corrolink S 1000

SKU: N/A Category:

SELECT OPTIONS 

Key Features & Benefits

  • Minimum roof pitch only 3°
  • Long trafficable unsupported span of up to 10.0m means less unsightly support beams
  • Lightweight and easy to install
  • Wiring services run through core ducts
  • Fire retardant EPS insulated core dramatically reduces radiant heat transfer, mould and condensation
  • Fire flashings available to suit up to BAL 40
  • LED downlights and ceiling fan mounting plates available
  • Solar panel installation engineering
  • Side eave overhang up to 450mm based on full width panel. Cantilever distance up to 2.89m
  • Panels customised to your cutback and lapping specs
  • Skylight strips now available in kits
  • Ceiling surface available in Smooth, Micraline, Luxline or Embossed in colours as shown.
CORROLINK-S (1000) SPAN TABLE
Wind Class in accordance with AS4055-2012Panel SizeMaximum Single Span
Wind Class in accordance with AS4055-2012Panel SizeFully Enclosed RoomOne Side OpenTwo/Three Sides Open
N1 (W28N)50mm751567767515
N1 (W28N)75mm895880778958
N1 (W28N)100mm934384259343
N1 (W28N)125mm 9742 87859742
N1 (W28N)150mm10000 (10618*)957410000 (10618*)
N1 (W28N)180mm10000 (11579*)10000 (10441*)10000 (11579*)
N2 (W33N)50mm625556726255
N2 (W33N)75mm745667617456
N2 (W33N)100mm777770527777
N2 (W33N)125mm810973538109
N2 (W33N)150mm883280148832
N2 (W33N)180mm963887399638
N3 (W41N)50mm492344734923
N3 (W41N)75mm587053355870
N3 (W41N)100mm612155616121
N3 (W41N)125mm640058106400
N3 (W41N)150mm695663206956
N3 (W41N)180mm758568927585
Other wind classesN4 (W50N) - C1 (W41C) - C2 (W50C) - C3 (W60C)
In accordance withWind actions: AS/NZS 1170.2:2011 - Clause 5.3, 5.4 and D4; Imposed load on roof: AS/NZS 1170.1:2002 - Clause 3.5
*Maximum manufactured ceiling length = 10000mm.
Maximum engineered spans used for cantilever lengths; cantilever ability of the panel is 25% of the maximum allowable span, provided there is double the desired cantilever as a backspan.
Maximum side eave achievable is 450mm, based on using a full width panel.
Fixing Details: Fixed to support member with 14g self drilling screws at every alternate crest.
Typically 7 screws to each panel, at each support. Request engineering specs for more information.

CORROLINK-S (1000) SPECIFICATIONS

Width

Length (Cut to Order)

Min. Roof Pitch

1000mm Cover

Min: 1800mm
Max: 15000mm

1°

Corrolink-S (1000) only available with Left Hand Lap and
60mm gutter cutback configuration

More Products from Zammit Versiclad Range

Back To Top
Enquiry Cart ×